Informix
Following are the reverse engineering options for Informix.
Parameter |
Description |
Additional Information |
---|---|---|
Reverse Engineer From | Specifies whether you want to reverse engineer from a script or database |
Database: Indicates that the model is reverse engineered from database Script File: Indicates that the model is reverse engineered from a script |
File | Specifies the script file location |
This option is available when Script File is selected. |
Parameter |
Description |
Additional Information |
---|---|---|
Glossary CSV File | Specifies the naming standard glossary file in the .CSV format |
|
Parameter |
Description |
Additional Information |
---|---|---|
Option Set | Specifies the option set template for reverse engineering |
Open: Use this option to open a saved XML option set file. Save: Use this option to save the configured option set. Save As: Use this option to save an option set either in the model or in the XML format at some external location. |
<Option Set Name> | Specifies the objects to be reverse engineered according to the selected option set. You can edit this list. |
Parameter |
Description |
Additional Information |
---|---|---|
System Objects | Specifies whether system databases are included under the Available Databases | |
Tables/Views Owned By | Specifies tables that are reverse engineered based on the ownership |
All: Indicates that all the tables are reverse engineered regardless of the owner Current User: Indicates that only those tables that are owned by the current user are reverse engineered Owners (comma separated): Indicates that only the tables owned by the users specified here are reverse engineered. Enter the usernames in capital letters. |
Infer | Specifies whether you want to infer primary keys or relationships, or both |
Primary Keys: Indicates that primary key columns are inferred for the tables that are based on defined indexes Relations: Indicates that the relationships between tables based on either primary key column names or defined indexes are inferred. Select this option and then specify whether to use primary key column names or defined indexes. The following options are available only when Infer is set to Relations. Indexes: Indicates that the relationships from the table indexes are inferred. Relationships are inferred from table indexes only if the primary key columns of the parent table are part of the index in the child table. Names: Indicates that the relationships from the primary key column names are inferred. Relationships are inferred from columns names only if all of the primary key columns of the parent are in the child table. |
Case Conversion of Physical Names | Specifies how the case conversion of physical names is handled |
None: Indicates that the case in the script file is preserved lower: Indicates that the names are converted to lower case UPPER: Indicates that the names are converted to upper case Force: Indicates whether the physical name property of all the logical/physical models is overridden. If this option is enabled, the logical/physical link is broken between the logical and physical name. If this option is not enabled, all logical and physical names are set to the same value after the process completes. |
Case Conversion of Logical Names | Specifies how the case conversion of logical names is handled |
None: Indicates that the case in the script file is preserved lower: Indicates that the names are converted to lower case UPPER: Indicates that the names are converted to upper case Mixed: Indicates that the mixed-case logical names are preserved |
Include Generated Triggers | Specifies whether erwin-generated triggers are loaded during the reverse engineering process |
Parameter |
Description |
Additional Information |
---|---|---|
Model | Specifies the location and name of the reverse engineered model | For example: C:\Scheduler\<Model Name>.erwin When you schedule a job on a remote server, ensure the model path is same for remote and local server. |
Mart Folder | Specifies the location or library in your mart where the reverse engineered model is saved | To use this option, ensure that you are connected to a mart. For more information, refer to the Connecting to Mart topic. |
Complete Compare | Specifies whether the Complete Compare (CC) process should run while reverse engineering | |
Output File | Specifies the location of the CC output file generated | |
File | Specifies that the target model location is on the local system | |
Mart | Specifies that the target model location is in the mart | |
Using Latest Version | Specifies whether the target model is the latest version of the model in the mart | This option is available only when Mart is selected. |
Save To Mart | Specifies whether the reverse engineered model is saved to the mart | This option is available only when Using Latest Version is selected. |
Target Model | Specifies the location of the target model for CC | |
Option Set | Specifies the option set that is used for CC |
Advanced Default Option Set: Indicates that all erwin DM metadata is included. CC works slowest with this option. Speed Option Set: Indicates that only the essential metadata is included. CC works the fastest with this option set. Standard Default Option Set: Indicates that standard metadata is included. CC works fast with this option set compared to the Advanced option set. |
Parameter |
Description |
Additional Information |
---|---|---|
erwin Project | Specifies whether to configure the model for an existing erwin project | |
Model Name | Specifies the name of the erwin project | |
Location | Specifies the location of the project |
Copyright © 2024 Quest Software, Inc. |