Scenario: Upgrading Mart Models › How to Upgrade Mart Models › Troubleshooting › Test Connection Failed--Source Mart
Test Connection Failed--Source Mart
Symptom:
The Mart Upgrade utility is not connecting to the source Mart.
This problem can be for one of the following reasons:
- The details for the source Mart are incorrect.
- The database client is not installed.
- The source database is not started.
- The source database is not able to connect from the client computer.
- The line SN=’Company Name’ in the r8 initializer file does not match with the r8 Workgroup Edition license file. This condition might occur when you upgrade from r7 to r8.
Solution:
Depending on the reason, use one of the following solutions:
- Ensure that the database details are correct.
- Ensure that a database client installed on the computer where you want to run the Mart Upgrade Utility.
- Ensure that the database is running.
- Ensure that you can connect to the source Mart with the database client installed on your computer.
- After upgrading your source Mart from r7 to r8, update the m7master.serialnumber field in the r8 source Mart database. Modify the value to include the same company name as SN="Company Name" in your r8 WorkGroup Edition license. Or, contact the CA Licensing department and get a new license for r8 with the required company name.
Back to Top
Copyright © 2015 CA Technologies.